Gold supplier gps container lock with track recording electronic fence and remote control function electronic safe lock

Short Description:

1.Main functional characteristics of the product: 1 ,built-in GPS module or Beidou module, 2, support 2G or 3G (WCDMA) network 3, the use of RFID electronic tag, support RFID card unlock function 4, the use of high strength plastic mold, lock body is not easy to destroy, passive failure will provide an alarm signal, can be anti fall, shock, waterproof, dust-proof. 5, high capacity battery, up to 15000MHA, can be connected to work for up to 7 days 6, built-in strong magnetic, can make the lo...


  • Min.Order Quantity: 10 Piece/Pieces
  • Supply Ability: 30000 Pieces per Month
  • Port: Shenzhen, China
  • Payment Terms: L/C,D/A,D/P,T/T
  • Product Detail

    Product Tags

    1.Main functional characteristics of the product:

    1 ,built-in GPS module or Beidou module,

    2, support 2G or 3G (WCDMA) network

    3, the use of RFID electronic tag, support RFID card unlock function

    4, the use of high strength plastic mold, lock body is not easy to destroy, passive failure will provide an alarm signal, can be anti fall, shock, waterproof, dust-proof.

    5, high capacity battery, up to 15000MHA, can be connected to work for up to 7 days

    6, built-in strong magnetic, can make the lock firmly adsorbed on the car body

    7, with low power alarm function, when the electricity is less than a certain value, the indicator light will start

    8, with buzzer prompt function, when the lock is not normally locked, the terminal will automatically issue beep alarm to remind the driver

    9, terminal with alarm reminders, when sewing is illegally cut off when the terminal will take the initiative to send alarm

    10, GPRS communication mode terminal, after each connection, automatically enter the GPS positioning mode, using TCP/IP and UDP protocol,

    11, remote configuration of the relevant logistics lock information.

    12, location information, switch status, electronic lock, instant information, etc..

    13, monitoring center remote authority unlock, IC card unlock mode, handheld unlock mode, SMS unlock mode, etc.

    14, monitoring center according to the pre-set location, range, vehicle overtime, route to regulate the logistics of walking routes, such as violations, real-time reporting, monitoring and so on.

    2. Product appearance / technical parameter:

    1. Product parameters: 

    Hardware features

     

    Hardware architecture

    Use STM32

    Communication module

    GPRS、WCDMA

    Technical specifications

     

    Operating Voltage

    3.6 V/DC

    Average operating current

    170

    RFID

    S70

    spare battery

    15000mAh continue working 7 days

    Dimensions

    335(with beam)mm*102mm*35mm

    Host weight

    1 KG

    Environmental characteristics

     

    Automotive EDM Interference Immunity

    Discharge voltage of 1kV ~ 2kV, discharge frequency of 20 times / s ~ 200 times / s 

    Fast Transient Burst Impedance

    4KV, experimental grade IV

    Electrostatic discharge immunity

    Contact discharge 6KV, air discharge 8KV, experimental grade Ⅲ

    Conducted harassment limits

    Meet the requirements of Class B

    Radiation disturbance limits

    Meet the requirements of Class B

    Temperature characteristics

    Operating temperature -40 ℃ ~ +75 ℃

    humidity

    5% to 95% non-condensing

    GPS performance

     

    Sensitivity

    -159dBm

    Positioning time

    Cold start less than 34 seconds; hot start less than 3.5 seconds; warm start less than 33 seconds, re-capture time 1.0 seconds 

    positioning accuracy

    10m

    Speed accuracy

    0.1m/s

    GSM / GPRS performance

     

    frequency

    850/ 900/ 1800/ 1900 MHz 

    Transmit power

    Class 4 (2W @ 850/ 900 MHz)Class 1(1W @ 1800/1900MHz)

    Operating temperature

    -40 °C to +85 °C

    data storage

     

    Blind sector cache

    Cache 2000 (point) location information

     

    2.Host LED status description:

    1.Green LED — Indicates GPS signal status

    State Definition
    Flash (flash once every 1 second) Searching for GPS signals.
    Slow flash (every 5 seconds flash) Has been targeted

    2.Red LED — indicates GSM status

    State State
    Flash (flash once every 1 second) Flash (flash once every 1 second)
    Slow flash (every 3 seconds flash) Slow flash (every 3 seconds flash)
    Frenzy (0.2 seconds flash 2S) Frenzy (0.2 seconds flash 2S)

    3.Blue LED — indicates the charge status

    State Definition
    not bright No charge or full charge
    Always bright The main power has been connected

    4.Orange LED — undervoltage indication status

    State Definition
    not bright Power is normal but no power
    Always bright The machine is currently in an undervoltage condition


    3
    .Set the machine parameters:

    After you have read the above description of the product, the product has been installed and the SIM card is installed. The following specific operation to start using.

     Note: So the SMS command should be entered in English mode, the command error or format error will not reply.

    1.Device IP address and Port

    Send the message to the device number on the instruction format:

    AS1234*F10#1,113.106.93.50,8011,1#

    Reply to terminal parameters

    IP:113.106.93.50,8011,1,cmnet,gprs,gprs,ID:31684086,M:6,GPS:A,9,CSQ:19,CGR:5,ACC:1,BAT:65%,VER:AT10-V1.0

    Such as:

    IP address:113.106.93.50 port:8011,TCP

    Order“AS1234*F10#1,113.106.93.50,8011,1#”

    The instruction is * AS *, “1234″ is the password, the initial default is 1234, “* F10 # 1″ means that this command is to set the machine’s IP instruction, 113.106.93.50 that the machine is connected to the server, 7001 for the port, 0 means the machine uses UDP to connect with the platform, if you want to use TCP to 1.

     2.Query terminal status   

    Send SMS to device number, instruction format

    AS1234STATE#

    Reply terminal parameter

    IP:113.106.93.50,8011,1,cmnet,gprs,gprs,ID:31684086,M:6,GPS:A,9,CSQ:19,CGR:5,ACC:1,BAT:65%,VER:AT10-V1.0

    IP: 113.106.93.50 Represents the server address reported by the current machine,

    Port: 7001 Represents the port of the current machine,0 means UDP Report,If it is 1 means TCP report

    Cmnet,gprs,gprs:means current device APN

    ID:31684086 means device ID number

    GPS:A,9 means the positioning state of the current machine, V means  no positioning,A means,9 mean 9 level accuracy

    CSQ:19,Mobile information for the current machine

    CGR:5 indicates the status of the card,

    ACC:1 indicates the status of the lock, the 1 is the unlock, and the 0 is the lock

    BAT:65% current lock capacity

    VER: AT10-V1.0 Represents the version that is currently burned by the machine

    M:6 That represents the current state of the machine, 6 online, 0 said 1 initialization, query CSQ, 2 registered network, 3 query the status of the CGREG, said the 4 registered APN, 5 said the connection to the server, 7 is disconnected from the network, said the 8 call, said 9 upgrade

    3.SMS unlock 

    Send SMS commands “AS1234*F10#8,888888, #” to the number of terminal equipment, the contents of the “Open lock OK replied,” to this content said off terminal unlock success

    The password can be unlocked remotely. For security, please consult the supplier to unlock the password.

    4.Set the unlock reporting frequency 

    Send SMS instructions“AS1234*F10#G,300,600,#”Number to device,The terminal replies to

    “accOn:300 accOff:600 rd:0 sp:0,0s stp:0 dr:0,0 idl:0 mv:0 time:+8 cq:0,0 geo:0 step:377 ack:0 msg:2568,56 sleep:0,0

    ”,The terminal has returned this content to indicate successful recovery

    ACCon:Represents the lock off reporting interval

    ACCoff:Represents the lock on reporting interval

    Sleep Represents sleep time

    5.Restore factory   

    Send SMS instructions“ASAX*%UPAS”Number to device,The terminal replies to“password:1234,OK”,The terminal has returned this content to indicate successful recovery

    6.Restart terminal   

    Send SMS instructions“AS1234RSGS#”To the number of the device, the terminal replies to“GSM/Restart;OK”,The terminal has returned this content to indicate a successful restart

    Attention:

    • All the SMS edit in English mode, Chinese mode input will lead directly to delete, do not reply sms.
    • All the messages are beginning to AS, to the end of #, format error will cause the application to not recognize.
    • The 1234 machine factory default password, if the password is wrong, will cause the application to not reply SMS

     


  • Previous:
  • Next: